| Instrument name
| Description
|
|
1
| Inductively coupled plasma mass spectrometry (ICP-MS)
| - Used to determine the elemental composition of various samples.
- It is a quadrupole ICP-MS system known for its ease of use, high throughput, and ability to deliver accurate results even in challenging sample matrices
- The detection limits of the instrument are able to achieve sub-ppt levels with the the innovative QCcell flatapole design, which allows comprehensive interference removal with helium Kinetic Energy Discrimination mode (He KED) or Chemical Reaction mode (CCT).
- The integrated Qtegra software provides ease-of- use operation experience.
|  |
2
| Microwave digestion milestone Ethos up High Performance Microwave Digestion System | - Used to prepare samples for various analytical techniques that measure the elemental composition of materials.
- The ETHOS UP is equipped with two 950 Watt magnetrons for a total of 1900 Watt making it the most powerful microwave digestion system available for sample preparation. The system additionally employs a rotating diffuser that evenly distributes the microwaves throughout the cavity.
- The new Milestone ETHOS UP microwave cavity has a volume of over 70 liters
- The ETHOS UP features a full stainless steel door with an innovative opening and self-resealing mechanism.
|
|
3
| Thermo Scientific Dionex UltiMate 3000 UHPLC system (Ultimate 3000 UHPLC DAD)
| - Used to separate, identify, and quantify the components of a mixture
- The system includes a robust pump that can deliver a wide range of flow rates and pressures.
- Controlled by the Chromeleon Chromatography Management System software, which provides intelligent control, data processing, and run automation.
- Suitable for diverse industries and research areas, including pharmaceutical, food and beverage, environmental, and clinical diagnostics
| |
4
| Bruker Tensor II FTIR
| Used to identify and characterize materials by analyzing their interaction with infrared light.
TENSOR II is the perfect choice for routine QA/QC and advanced R&D applications in industry and academia.
TENSOR II provides a smooth and complete solution for your analytical work flow. To perform your sample analysis just follow the guideline of the intuitive soft ware step-by-step.
| |
5
| Differential Scanning Calorimetry (DSC 3500 Sirius)
| - Used to measure the amount of heat released or absorbed by a sample during heating or cooling over a range of temperature.
- The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from -170°C to 600°C.
- The heating wires of the furnace surround the entire sensor plate. They are arranged in such a way that no temperature gradients occur in or above the sensor disk.
- Protective and purge gas inlets are, of course, standard features of the unit. For improved cooling times and subambient temperature tests, various cooling options can be connected. Of course, a versatile gas switching and flow control system are also available.
|  
|
6
| Thermal Constant
| - Used to measure a material's thermal properties, specifically thermal conductivity, thermal diffusivity, and specific heat capacity.
- The TPS 2200 is used in various industries, including aerospace, automotive, materials science, and semiconductor manufacturing. It's also used in quality control and research and development labs.
- The TPS 2200 utilizes the TPS method, a non-destructive and accurate technique for measuring thermal properties.
- Accommodating various sample geometries and operating across a broad temperature range
- A selection of optional measurement modules allows the TPS 2200 to be used in several specialized applications, from precise testing of isotropic materials , to measurements of slab samples; anisotropic samples or layered structures ; thin films or coatings . And extremely light and low-conducting materials . Also featured is direct testing of specific heat capacity of bulk samples .
|  |
7
| Fluorescence spectrophotometer | - Used for quantitative measurements of chemical products. Fluorescence spectroscopy analyzes fluorescence from a molecule based on its fluorescent properties.
- The Cary Eclipse fluorescence spectrophotometer is able to scan at 24 000 nm/min without peak shifts due to the design of the monochromator drive mechanism. The grating is moved only when the lamp is off, resulting in a go-stop-flash method of taking a measurement. The wavelength does not change whilst a measurement is being taken.
• Signal-to-noise mode is a unique method of collecting data that allows you to control the level of precision you want across the whole scan. The instrument will scan quickly in areas of high emission and slow down in areas where the emission is less.
|

|
8
| Dr 5000 UV-Vis spectrophotometer | - Used to measure the absorbance and transmittance of ultraviolet and visible light through a sample
- Maximum analysis flexibility with high speed wavelength scanning across the UV and visible spectrum
- Easily Add New Analytical Methods
- Multiple Cell Sizes and Delivery Methods
- Large Touch Screen Display and Interface.
| |
9
| Linseis TGA PT1000
| - Used to measure the change in weight of a material as a function of temperature or time
- The LINSEIS TGA 1000 is a robust and reliable TGA outperforming most competition high end models.
- The sub microgram balance offers highest sensitivity and resolution.
- The instrument is perfectly suited for academic teaching and day to day laboratory quality control applications.
| |
10
| Freeze Dryer | - Used to remove moisture through a process called sublimation.
- Because the freeze drying process does not use heat to remove water, the enzymes and terpenes in freeze dried products are not destroyed.
| |
11
| Computerized Electronic Universal Testing Machine (WDW-2E)
| - Used to determine the strength, rigidity, and other mechanical properties of materials under tension.
- WDW-2E machines are used for testing materials like: Metals (steel, iron, etc.) Non-metals (rubber, plastics, etc.) Composites Textiles Springs Building components Automotive and aerospace structures And many more
| |